Solenoid bolt Prima series
|_
Solenoid bolt for aluminium mid-rail

 

Connection between Solenoid bolt and console can be done with Plug- In module

 

Solenoid bolt with anti-rebound ball

 

For double interlocking doors

 

Lock for interlocking system

 

Fail Safe

 

 

 

Solenoid bolt Art. 24600
Solenoid bolt with handle square 8mm Art. 24608
Solenoid bolt with handle square 9mm Art. 24609

Internal microprocessor electronic to control the movements of the locks such that their movements succeed each other in a predetermined sequence, assuring that opening cannot be simultaneously.

Mechanical opening with European profile cylinder

Mortice applicaton

Front plate in s/steel 320 x 25 x 3 mm.

Counterplate in s/steel 150 x 25 x 3 mm.with magnet adjustable in extension

Revolving bolt in anticutting hardened steel with mechanical block on closed position

Bolt dimensions : extension 20 mm. (25 mm. in version XL), diameter 16 mm.

Operating voltage : 12/24 Vdc

Absorbed current : 2.5 A of peak / 130 mA for maintenance with electronic control

Connection by quick connector

Arranged for interlock connection between 2 or more doors

N.O. contact for Opening Bolt position free voltage contact C. / N.O. / N.C.

Door position contact N.O. for the Open/Closed monitoring function or for use of outside door alignment sensor

Opto-electronic bolt position control

Internal magnetic sensor for door position

Push buttons for monitoring and adjustment of reclosing times from 0-5 sec. to approach of door and from 0-60 sec. if the door is not opened.

Timings can be turned off for use of solenoid bolt with outside management electronics

Traffic Indicator Lights Relay outputs are available to control traffic lights.

For user convenience, a green light is typically used to signify a door is ready for access. A red light is usually lit to indicate that a door is un-accessible. Alarm relay outputs are also available for special requirements.

 

 

For double interlocking doors

 

 

Lock for interlocking system

 

Fail secure

 

 

 

 

Solenoid bolt Art. 24800
Solenoid bolt with handle square 8mm Art. 24808
Solenoid bolt with handle square 9mm Art. 24809

Internal microprocessor electronic to control the movements of the locks such that their movements succeed each other in a predetermined sequence, assuring that opening cannot be simultaneously.

Mechanical opening with European profile cylinder

Mortice applicaton

Front plate in s/steel 320 x 25 x 3 mm.

Counterplate in s/steel 150 x 25 x 3 mm.with magnet adjustable in extension

Revolving bolt in anticutting hardened steel with mechanical block on closed position

Bolt dimensions : extension 20 mm. (25 mm. in version XL), diameter 16 mm.

Operating voltage : 12/24 Vdc

Absorbed current : 2.5 A of peak / 130 mA for maintenance with electronic control

Connection by quick connector

Arranged for interlock connection between 2 or more doors

N.O. contact for Opening Bolt position free voltage contact C. / N.O. / N.C.

Door position contact N.O. for the Open/Closed monitoring function or for use of outside door alignment sensor

Opto-electronic bolt position control

Internal magnetic sensor for door position

Push buttons for monitoring and adjustment of reclosing times from 0-5 sec. to approach of door and from 0-60 sec. if the door is not opened.

Timings can be turned off for use of solenoid bolt with outside management electronics

Traffic Indicator Lights Relay outputs are available to control traffic lights.

For user convenience, a green light is typically used to signify a door is ready for access. A red light is usually lit to indicate that a door is un-accessible. Alarm relay outputs are also available for special requirements.