Mortice electric strike for armoured doors You are in the English version

 

 

 

 

 

 

mm 93x36x21

How to determine handing

 

 

Electric strike for armoured door  

Fail secure electric strike for armour plated doors

Opening limited to impulse duration

Destruction resisting power : 700Kg

Art.37012.1 - Right hand - Operating voltage 12Vac -500mA

Art.37012.2 - Left hand - Operating voltage 12Vac -500mA

Art.37012.1 - MIC- Right hand - Latch position microswitch C./N.O./N.C. Operating voltage 12Vac - 500mA

Art. 37012.2 - MIC- Left hand - Latch position microswitch C./N.O./N.C. Operating voltage 12Vac - 500mA

Art. 37612.1- MIC- Right hand - Latch position microswitch C./N.O./N.C. Operating voltage 12Vdc - 200mA

Art.37612.2 - MIC- Left hand - Latch position microswitch C./N.O./N.C. Operating voltage 12Vdc - 200mA

 

 

 

mm 93x36x21

How to determine handing

 

 

Electric strike for armoured door  

Fail secure electric strike for armour plated doors with incorporated anti-repeater.

Opening with impulse

Destruction resisting power : 700Kg

Art. 37412.1 Right hand - Operating voltage 12Vac - 500mA

Art. 37412.2 Left hand - Operating voltage 12Vac - 500mA

Art. 37512.1 Right hand - With "open" release lever - Operating voltage 12Vac - 500mA

Art. 37512.2 Left hand - With "open" release lever - Operating voltage 12Vac - 500mA

 

 

 

mm 93x36x21

How to determine handing

Electric strike for armoured door  

Fail safe Electric strike for armour plated doors

Opening limited to impulse duration

Destruction resisting power : 700Kg

Art. 37812.1 Right hand-Operating voltage 12 Vdc – 200 mA

Art. 37812.2 Left hand-Operating voltage 12 Vdc – 200 mA

Art. 37812.1 MIC Right hand-Operating voltage 12 Vdc – 200 mA - Latch position microswitch C./N.O./N.C.

Art. 37812.2 MIC Left hand-Operating voltage 12 Vdc – 200 mA - Latch position microswitch C./N.O./N.C.

 

 

 

 

mm 91x32x23

How to determine handing

Electric strike for armoured door  

Fail secure electric strike for armour plated doors

Destruction resisting power : 1000Kg

Protected against umidity and water ( IP65)

Art. 38012.1 Right hand - Operating voltage 12 Vac – 500 mA without anti repeater. Opening limited to impulse duration

Art. 38012.2 Left hand - Operating voltage 12 Vac – 500 mA without anti repeater. Opening limited to impulse duration

Art. 38412.1 Right hand-Operating voltage 12 Vac with anti repeater. Opening with impulse

Art. 38412.2 Left hand-Operating voltage 12 Vac with anti repeater. Opening with impulse

 

Tools
Printing version

 

 

 

Related products
  Front plate
  Power supply and batteries